Disgrifiad o'r cynnyrch:
Diwydiant Cynhyrchion Qualtech Sgäl Labordy yw Clorian Ddadansoddol Electronig o Uchel Fanwl ar gyfer pwyso samplau yn broffesiynol ac ar unwaith â manwl uchel, gan gynnwys samplau solet, powdrau a hylifau, ar gyfer ymchwil a rheoli ansawdd.
Y proffesiynol hwn Sgäl Dadansoddol Labordy yn cynnig y dechnoleg micro-glip ddiweddaraf wedi'i chyfuno â Chyflwyniad LCD Lliw mawr, cyfforddus i'w ddarllen, Botymau Meddal-gyffwrdd cyfforddus, Amgaead Gwydr cyfleus ar gyfer mwy o gywirdeb pwyso, Cywirdeb Uchel a Manwl Uchel, Calibru Awtomatig, Modd Mesur Samplau Ar Unwaith, Mesur Samplau Awtomatig, Trawsnewid Unedau gan gynnwys g, ct, ozt. lb a mwy, Ap symudol hawdd ei ddefnyddio, Rhaglennu hawdd ei ddefnyddio, Trin samplau hawdd ei ddefnyddio, cyfrifydd integredig, Argraffu uniongyrchol, cysylltedd PC di-dor dewisol a Meddalwedd PC, dyluniad ergonomig, perfformiad dibynadwy a llawer mwy.
Y proffesiynol hwn Clorian Labordy yw synergedd o dechnoleg mesur samplau ddatblygedig, cymhwysiad hawdd ei ddefnyddio a chywirdeb uchel ar gyfer ymchwil a rheoli ansawdd.
Mae'r glorian labordy dadansoddol fanwl gywir hon wedi'i dylunio a'i pheiriannu yn unol â safonau profi rhyngwladol.
Professional Applications and Operation of the QPI-PS120 Laboratory Precision Balance:
Precision mass measurement serves as the foundation for modern scientific research, industrial quality control, and advanced material synthesis. Whether formulating complex chemical reagents, conducting gravimetric analysis, or performing precise sample preparation for spectroscopy, accurate weight data directly dictates the reliability of downstream experimental results.
Y Qualtech Products Industry Laboratory Precision Balance (Model QPI-PS120) is engineered to meet the stringent demands of laboratory workflows, providing sub-milligram readability, fast response times, and robust operational stability. This guide explores the core technical architecture, essential applications, and best operational practices for utilizing the QPI-PS120 in professional laboratory and educational environments.
Technical Architecture & Performance Capabilities
The QPI-PS120 integrates high-performance microchip processing with a heavy-duty load cell assembly to deliver precise measurements under variable laboratory conditions. Key performance characteristics include:
High Readability (0.001 g / 1 mg): Enables precise determination of small sample masses, suitable for fine chemical dosing and micro-titration prep.
Maximum Capacity (120 g): Accommodates standard laboratory glassware, weighing boats, and crucible hardware alongside target samples.
Integrated Draft Shield: Eliminates local micro-drafts, thermal convection currents, and atmospheric disturbance during measurement.
RS232 Data Interface: Provides direct connectivity to external printers, computers, and Laboratory Information Management Systems (LIMS) for seamless data logging.
Primary Applications in Research and Industry
1. Gravimetric Analysis and Reagent Preparation
In analytical chemistry, gravimetric techniques require accurate mass measurement before and after chemical transformations (such as precipitation, evaporation, or combustion). The QPI-PS120 allows researchers to measure accurate initial precursor masses and determine precise yield percentages, minimizing compounding errors in stoichiometry calculations.
2. Textile and Material Density Testing
When paired with circular sample cutters (such as GSM cutters) or specific density determination kits, the QPI-PS120 measures the surface weight (g/m²) of textiles, paper, polymers, and foil samples. Precision down to 0.001 g is critical when evaluating thin-film coatings, non-woven fabrics, and high-performance technical textiles where slight variations indicate manufacturing flaws.
3. Quality Assurance (QA) and Quality Control (QC)
Industrial manufacturing facilities—ranging from pharmaceutical production to specialized rubber and plastic synthesis—rely on strict batch consistency. QC technicians use the QPI-PS120 to verify component ratios, measure sample moisture loss during drying cycles, and audit finished product tolerances against ASTM, ISO, and DIN standards.
4. Advanced Academic Instruction
For engineering and chemistry students, mastering high-precision laboratory balances builds core laboratory competence. The QPI-PS120 provides an intuitive interface with standard tactile function keys (Tare, Unit Conversion, Calibration), allowing students to focus on fundamental principles of measurement uncertainty, buoyancy corrections, and error analysis without navigating overly complex menu trees.
Step-by-Step Standard Operating Procedure (SOP)
To maintain measurement accuracy and extend instrument lifespan, operators should follow standard weighing protocols:
Environmental Setup: Place the balance on a stable, vibration-free granite or heavy laboratory bench away from direct sunlight, HVAC vents, and magnetic interference. Level the unit using the adjustable leveling feet and the integrated bubble spirit level.
Warm-Up Phase: Connect the unit to standard AC power and allow a 15- to 30-minute warm-up period to stabilize internal electronic components thermally.
Draft Shield Management: Ensure all sliding glass doors are fully closed prior to zeroing or recording final readings.
Zeroing and Taring: Place your clean weighing vessel (weighing paper or boat) onto the center of the stainless steel pan. Press the Tare key to zero out the container weight.
Llwytho Sampl: Carefully introduce the sample material into the vessel using a clean spatula. Avoid spilling reagents directly onto the pan or lower chamber housing.
Reading Final Mass: Allow the digital display stabilization indicator to illuminate before recording the value or transferring data via the RS232 port.
Calibration and Routine Maintenance
Regular calibration ensures measurement traceability to national metrology standards. The QPI-PS120 supports automated calibration routines using external standard weights (e.g., F1 Class calibration masses).
Routine Daily Checks: Clean the weighing chamber with a soft brush or lint-free cloth. Remove any spilled particulates immediately to prevent corrosion or mechanical binding.
Periodic Calibration: Perform a full span calibration weekly or whenever the balance is relocated, subjected to significant ambient temperature shifts, or power-cycled.
Handling Standards: Always handle calibration weights using non-magnetic tweezers or cotton gloves to prevent oil transfer from hands, which can alter sub-milligram mass values.
By adhering to proper calibration schedules and environmental precautions, the QPI-PS120 delivers consistent, repeatable, and traceable measurement results across all academic and industrial testing workflows.
Clorian Pwyso Manwl Uchel – Nodweddion:
- Technoleg Micro-sglodyn ddiweddaraf
- Pwyso Labordy Proffesiynol Ar Unwaith
- Arddangosfa LCD Fawr gyda Chefn-oleuadau
- Botymau Meddal Cyfforddus
- Arddangosfa cydraniad uchel
- Cloyfan Gwydr
- Cais hawdd ei ddefnyddio
- Rhaglennu hawdd ei ddefnyddio
- Trin Samplau Hawdd ei Ddefnyddio
- Trawsnewid Awtomatig o Bwysau Gros i Bwysau Net
- Trawsnewid Unedau gan gynnwys g, CT, OZ, lb a llawer mwy
- Arwyddion LED
- Calibru Awtomatig
- Cysylltedd PC di-dor dewisol
- Cywirdeb Uchel a Manwl-gywirdeb Uchel
- Dyluniad Ergonomig a Pherfformiad Dibynadwy
- Dyluniad Cadarn a Hirhoedledd
- Peirianyddwyd yn unol â safonau profi rhyngwladol
Clorian Labordy – Manylebau:
| Model | Capasiti Llwyth Uchaf | Penderfyniad | Maint y Platfform | Glôb Corwynt |
|---|---|---|---|---|
| QPI-PS50 | 110 g | 0.1 mg | Ø 80 mm | Ategolyn dewisol |
| QPI-PS60 | 120 g | 0.1 mg | Ø 80 mm | Ategolyn dewisol |
| QPI-PS70 | 160 g | 0.1 mg | Ø 80 mm | Ategolyn dewisol |
| QPI-PS80 | 210 g | 0.1 mg | Ø 80 mm | Ategolyn dewisol |
| QPI-PS90 | 220 g | 0.1 mg | Ø 80 mm | Ategolyn dewisol |
| QPI-PS100 | 100 g | 0.001 g | Ø 80 mm | Ategolyn dewisol |
| QPI-PS110 | 200 g | 0.001 g | Ø 80 mm | Ategolyn dewisol |
| QPI-PS120 | 300 g | 0.001 g | Ø 80 mm | Ategolyn dewisol |
| QPI-PS130 | 400 g | 0.001 g | Ø 80 mm | Ategolyn dewisol |
| QPI-PS140 | 500 g | 0.001 g | Ø 80 mm | Ategolyn dewisol |
| QPI-PS150 | 600 g | 0.001 g | Ø 80 mm | Ategolyn dewisol |
| QPI-PS160 | 1000 g | 0.001 g | Ø 80 mm | Ategolyn dewisol |
| QPI-PS170 | 1200 g | 0.001 g | Ø 80 mm | Ategolyn dewisol |
| QPI-PS125 | 110 g | 0.01 g | Ø 125 mm | Ategolyn dewisol |
| QPI-PS135 | 210 g | 0.01 g | Ø 125 mm | Ategolyn dewisol |
| QPI-PS145 | 310 g | 0.01 g | Ø 125 mm | Ategolyn dewisol |
| QPI-PS155 | 510 g | 0.01 g | Ø 125 mm | Ategolyn dewisol |
| QPI-PS165 | 610 g | 0.01 g | Ø 125 mm | Ategolyn dewisol |
| QPI-PS1000 | 1,100 g | 0.01 g | Ø 125 mm | Ategolyn dewisol |
| QPI-PS1100 | 2,100 g | 0.01 g | Ø 125 mm | Ategolyn dewisol |
| QPI-PS1300S | 5,100 g | 0.01 g | Ø 180 mm | Ategolyn dewisol |
| QPI-PS1300 | 3,100 g | 0.1 g | 155 mm x 175 mm | Ategolyn dewisol |
| QPI-PS1600 | 8,000 g | 0.1 g | 160 mm x 180 mm | Ategolyn dewisol |
| Cywirdeb Uchel a Manwl-gywirdeb Uchel | Ie | Ie | Ie | Ie |
| Dyluniad Ergonomig a Pherfformiad Dibynadwy | Ie | |||
| Foltedd | 100VAC - 240VAC 50Hz/60Hz | |||
| Peirianyddwyd yn unol â safonau prawf rhyngwladol cydnabyddedig | ||||
Sgales Labordy Pwyso Manwl Uchel – Eitemau wedi'u cynnwys:
- Clorian Labordy Awtomatig o Gywirdeb Uchel
- Ategolion
- Pwysau graddnodi
- Addasydd pŵer
- Tystysgrif Ansawdd
- Graddnodedig yn ofalus
- Tystysgrif Graddnodi
- Llawlyfr defnyddiwr
- Gwarant estynedig
Cewch wybodaeth nawr am gynhyrchion, prisiau, cymorth technegol a gwasanaethau proffesiynol.