QUALTECH PRODUCTS INDUSTRY

QUALTECH PRODUCTS INDUSTRY

Paint & Coating Test Instruments

Real Values For Our Customers & Clients

QUALTECH PRODUCTS INDUSTRY

Industrial Production Equipment

Industrial Scale Machinery For Production Lines

Reliable Equipment For Your Products

QUALTECH PRODUCTS INDUSTRY

Chemicals For Paint Production

Pigments & Binders & More

Chemicals To Support Your Products

QUALTECH PRODUCTS INDUSTRY

Real Values For Our Customers & Clients

Reliable Quality

Professional Service

QUALTECH PRODUCTS INDUSTRY

Reliable Quality

High Technology

Professional Service

PREV
NEXT

Register here for Updates & News

Product Description:

Qualtech Products Industry Karl Fischer Titrator is a precision Automatic Karl Fischer Titration System for the professional measurement of the Moisture Content and the Water Content of samples in accordance with the Volumetric Titration Method and the Volumetric Karl Fischer Method.

This professional Automatic Volumetric Karl Fischer Titrator is engineered to measure the moisture content and the water content of samples within the full range with the Volumetric Karl Fischer Test Method.

The Karl Fischer Test Method is performed with two different Karl Fischer Titration Test Methods each offering advantages which might indicate which Karl Fischer Titration Test Method may be best suited for a specific Water Content Measurement Application:

  • Volumetric Karl Fischer Titrator
  • Coulometric Karl Fischer Titrator

The Volumetric Karl Fischer Titration Method is usually best suited for samples with an expected Water Content of more than 1%. The Volumetric Karl Fischer Titrator requires a specialized Karl Fischer Reagent to perform the Water Content Analysis which has a specified titer which may change over time and requires frequent verification with a Calibrated Water Standard. The Volumetric Karl Fischer Method is less accurate compared to the Coulometric Karl Fischer Titrator but is suitable for larger sample volumes.

The Coulometric Karl Fischer Titration Method is usually best suited for samples with an expected Water Content across the full range from 0.0% - 100.0% and offers a much higher accuracy compared to the Volumetric Karl Fischer Titrator, hence the Coulometric Karl Fischer Titrator is also suitable for samples with a very low Water Content below 1%. Based on the high accuracy of the Colulometric Karl Fischer Titrator it is often referred to as the 'Absolute Karl Fischer Method'. The Coulometric Karl Fischer Sample Container has two compartments, one compartment is for the Anode, the second compartment is for the Kathode. The Volumetric Karl Fischer Titrator offers a higher accuracy and completes sample tests faster compared to the Volumetric Karl Fischer Titrator. In addition, the Coulometric Karl Fischer Titrator doesn't require an ongoing calibration for the Karl Fischer Reagent and the Solvent doesn't need to be replaced after each sample tests allowing for possibly lower ongoing costs and a more convenient application.

This professional Automatic Volumetric Karl Fischer Titrator offers the newest microchip technology for Volumetric Karl Fischer Titration combined with a closed system for advanced user safety, a large LCD Display with Backlight, a Non-Pollution System & Non-Leakage System, Fully-Automatic Sample Dispensing, Fully-Automatic Sample Discharge, Fully-Automatic Karl Fischer Reagent Dispensing, Automatic Cleaning, Advanced Safety Features, a wide range of integrated Automatic Titration Programs, a large integrated Sample Measurement Data Memory, comfortable Softtouch Buttons, user-friendly programming, user-friendly Menu Navigation, Advanced Real Time Monitoring, high accuracy, high precision, an ergonomic design, reliable performance, longevity and much more.

This precision Volumetric Karl Fischer Titrator is the recommended Moisture Measurement Instrument for research and quality management including chemical laboratories, pharmaceutical laboratories, petrochemical laboratories, food test laboratories, agricultural laboratories, cosmetic laboratories and many more.

This professional Karl Fischer Titrator is designed and engineered in accordance with the Volumetric Karl Fischer Titration Method two professional titration methods to measure the trace amount of water and moisture in samples.

The Karl Fischer Titration includes two Moisture Measurement Test Methods:

  • Coulometric Karl Fisher Method
  • Volumetric Karl Fisher Method

The main principles of both titration methods are related. The Coulometric Titration System is highly sensitive to moisture. It is ideal to determine the water content of samples as low as 0.1 µg and a moisture content of ≤ 200 µg. The Coulometric Titration Method offers highest precision and highest accuracy and is best suitable for samples with a very low moisture content in the range from 0.0% to 1.0%.

The Volumetric Titration System is less sensitive to moisture and water content compared to the Coulometric Titration System and is best suitable to determine a moisture content of samples with a higher water and moisture content in the range from 1% to 100%.

This Automatic Volumetric Karl Fischer Titrator offers a wide range of practical advantages over other methods of moisture determination including automatic testing, user-friendly sample handling, high precision, high repeatability.

This professional Volumetric Karl Fisher Titrator is designed and engineered in accordance with international test standards including:

Volumetric Karl Fischer Titrator – Application:

The Karl Fischer Titrator is a precision Automatic Karl Fischer Titration System for the professional measurement of the Moisture Content and the Water Content of samples in accordance with the Volumetric Titration Method and the Volumetric Karl Fischer Method.

The professional Automatic Volumetric Karl Fischer Titrator is engineered to measure the moisture content and the water content of samples within the full range with the Volumetric Karl Fischer Test Method.

The Karl Fischer Test Method is performed with two different Karl Fischer Titration Test Methods each offering advantages which might indicate which Karl Fischer Titration Test Method may be best suited for a specific Water Content Measurement Application:

  • Coulometric Karl Fischer Titrator
  • Volumetric Karl Fischer Titrator

The Volumetric Karl Fischer Titration Method is usually best suited for samples with an expected Water Content of more than 1%. The Volumetric Karl Fischer Titrator requires a specialized Karl Fischer Reagent to perform the Water Content Analysis which has a specified titer which may change over time and requires frequent verification with a Calibrated Water Standard. The Volumetric Karl Fischer Method is less accurate compared to the Coulometric Karl Fischer Titrator but is suitable for larger sample volumes.

The Coulometric Karl Fischer Titration Method is usually best suited for samples with an expected Water Content across the full range from 0.0% - 100.0% and offers a much higher accuracy compared to the Volumetric Karl Fischer Titrator, hence the Coulometric Karl Fischer Titrator is also suitable for samples with a very low Water Content below 1%. Based on the high accuracy of the Colulometric Karl Fischer Titrator it is often referred to as the 'Absolute Karl Fischer Method'. The Coulometric Karl Fischer Sample Container has two compartments, one compartment is for the Anode, the second compartment is for the Kathode. The Volumetric Karl Fischer Titrator offers a higher accuracy and completes sample tests faster compared to the Volumetric Karl Fischer Titrator. In addition, the Coulometric Karl Fischer Titrator doesn't require an ongoing calibration for the Karl Fischer Reagent and the Solvent doesn't need to be replaced after each sample tests allowing for possibly lower ongoing costs and a more convenient application.

This precision Volumetric Karl Fischer Titrator is the recommended Moisture Measurement Instrument for research and quality management including chemical laboratories, pharmaceutical laboratories, petrochemical laboratories, food test laboratories, agricultural laboratories, cosmetic laboratories and many more.

The Karl Fischer Titration includes two Moisture Measurement Test Methods:

  • Coulometric Karl Fisher Method
  • Volumetric Karl Fisher Method

The main principles of both titration methods are related. The Coulometric Titration System is highly sensitive to moisture. It is ideal to determine the water content of samples as low as 0.1 µg and a moisture content of ≤ 200 µg. The Coulometric Titration Method offers highest precision and highest accuracy and is best suitable for samples with a very low moisture content in the range from 0.0% to 1.0%.

The Volumetric Titration System is less sensitive to moisture and water content compared to the Coulometric Titration System and is best suitable to determine a moisture content of samples with a higher water and moisture content in the range from 1% to 100%.

This Automatic Volumetric Karl Fischer Titrator offers a wide range of practical advantages over other methods of moisture determination including automatic testing, user-friendly sample handling, high precision, high repeatability.

Advanced Karl Fischer Titrator – Features:

  • Newest Microchip Technology
  • Volumetric Karl Fischer Method & Coulometric Karl Fischer Method
  • Non-Pollution System & Non-Leakage System
  • Fully-Automatic Sample Dispensing
  • Fully-Automatic Sample Discharge
  • Fully-Automatic Karl Fischer Reagent Dispensing
  • Automatic Cleaning
  • Select from a wide range of integrated Titration Programs
  • Select from a wide range of Measurement Units including 'ppm', 'mg', 'mg/L', '%'
  • Large Integrated Sample Measurement Data Memory Chip
  • Comfortable Softtouch Buttons
  • User-friendly Programming
  • User-friendly Menu Navigation
  • Advanced Real Time Monitoring
  • High Accuracy & High Precision
  • Ergonomic Design
  • Reliable Performance & Longevity
  • Engineered in accordance with international test standards including ASTM D4377, ASTM D6869, ISO 1522

Advanced Karl Fischer Titrator – Specifications:

ModelQPI-VCT6800
Newest Microchip TechnologyYes
Volumetric Measuring Range0.1 mg - 250.0 mg
Coulometric Measuring Range10 µg - 20 mg
Volumetric Method Unitsmg, mg/L, ppm, %
Coulometric Method Unitsµg, µg/L, mg, mg/L, ppm, %
Polarization Current1 ±0.2 µA
50 ±10 µA
Electrolyt Current10 mA
20 mA
50 mA
100 mA
Accuracy Volumetric Test≤0.5%
Accuracy Coulometric Test≤3%
Automatic Titration ProgramsYes
Closed System for Advanced SafetyYes
Non-Pollution SystemYes
Non-Leakage SystemYes
Fully-Automatic Sample DispensingYes
Fully-Automatic Sample DischargeYes
Fully-Automatic Karl Fischer Reagent DispensingYes
Automatic CleaningYes
Voltage110 Volts 60 Hz & 220 Volts 50 Hz
Seamless PC-Connectivity & PC-SoftwareYes
Ergonomic Design & Reliable PerformanceYes
Engineered in accordance with international test standards including ASTM D4377, ASTM D6869, ISO 1522

Automatic Volumetric Karl Fischer Titrator – Included items:

  • Automatic Volumetric Karl Fischer Titrator for Volumetric & Coulometric Test Method
  • Carefully Calibrated
  • Calibration Certificate
  • Quality Certificate
  • User manual
  • Extended Warranty
  • Lifetime Support

Get information now on products, pricing, technical support and professional services.
One of our specialists will reply to your enquiry shortly. Alternatively contact us via the company details in the USA, in Australia or in the UK.

View some of our valued clients:

Laboratory Test Instruments
TOP
en_USEnglish